Gas Boosters to 100 bar (1,450psi)

Note : pA = Gas Inlet pressure / pL = Air drive pressure / pB = Gas Outlet pressure

Model

Pressure Ratio

Max Compression ratio

Stage ratio

Min gas inlet pressure pA in bar (psi)

Max gas inlet pressure pA in bar (psi)

Max permitted outlet pressure pB in bar (psi)

Formula to calculate gas outlet pressure pB

Displacement volume in cm3 (ins3)

Air drive pL in bar (psi)

Air consumption in L/min

Gas inlet connection

Gas outlet connection

Air Drive connection

Net weight (kg)

DLE 5-GG

1:5

1:15

2 (29)

100 (1,450)

100 (1,450)

5 X pL + pA

746 (45.52)

1-10 (14.5-145)

400-1,980 (14.1– 69.9)

1/2 BSP

1/2 BSP

3/4 BSP

20

DLE 2-5-GG

1:5/1.5

1:25

1:2.5

0

0.8 x pL

100 (1,450)

5 X pL + 2.5 x pA

922 (56.26)

1-10 (14.5-145)

400-1,980 (14.1– 69.9)

1/2 BSP

1/2 BSP

3/4 BSP

20

DLE 5-1-2-GG

1:10

1:15

4(58)

100 (1,450)

100 (1,450)

10 X pL

373 (22.76)

1-10 (14.5-145)

600-2,400 (21.2-84.8)

1/2 BSP

1/2 BSP

3/4 BSP

22

DLE 5-2-GG

1:10

1:15

4 (58)

100 (1,450)

100 (1,450)

10 X pL + pA

746 (45.52)

1-10 (14.5-145)

600-2,400 (21.2-84.8)

1/2 BSP

1/2 BSP

3/4 BSP

25

Model

Pressure Ratio

Max Compression ratio

Stage ratio

Min gas inlet pressure pA in bar (psi)

Max gas inlet pressure pA in bar (psi)

Max permitted outlet pressure pB in bar (psi)

Formula to calculate gas outlet pressure pB

Displacement volume in cm3 (ins3)

Air drive pL in bar (psi)

Air consumption in L/min

Gas inlet connection

Gas outlet connection

Air Drive connection

Net weight (kg)

DLE 2-5-2-GG

1:4 / 1:10

1:25

1:2.5

0

1.6 x pL

100 (1,450)

10 X pL + 2.5 pA

922 (56.26)

1-10 (14.5-145)

600-2,400 (21.2-84.8)

1/2 BSP

1/2 BSP

3/4 BSP

25