✅
Pressure Ratio
Max Compression ratio
Stage ratio
Min gas inlet pressure pA in bar (psi)
Max gas inlet pressure pA in bar (psi)
Max permitted outlet pressure pB in bar (psi)
Formula to calculate gas outlet pressure pB
Displacement volume in cm3 (ins3)
Air drive pL in bar (psi)
Air consumption in L/min
Gas inlet connection
Gas outlet connection
Air Drive connection
Net weight (kg)
1:30
1:20
–
15 (217)
600 (8,700)
600 (8,700)
30 x pL + pA
110 (6.71)
1-10 (14.5-145)
400-1,980 (14.1– 69.9)
1/4 BSP
1/4 BSP
3/4 BSP
18
1:5 / 1:30
1:90
1:6
2 (29)
2 x pL
600 (8,700)
30 x pL + 6 x pA
373 (22.76)
1-10 (14.5-145)
400-1,980 (14.1– 69.9)
1/2 BSP
1/4 BSP
3/4 BSP
19
1:5 / 1:30
1:40
1:2
7 (101)
15 x pL
600 (8,700)
30 x pL + 2 x pA
122 (7.44)
1-10 (14.5-145)
400-1,980 (14.1– 69.9)
1/4 BSP
1/4 BSP
3/4 BSP
19
1:60
1:20
–
20(290)
600 (8,700)
600 (8,700)
60 x pL
60 (3.66)
1-10 (14.5-145)
600-2,400 (21.2-84.8)
1/4 BSP
1/4 BSP
3/4 BSP
20
Pressure Ratio
Max Compression ratio
Stage ratio
Min gas inlet pressure pA in bar (psi)
Max gas inlet pressure pA in bar (psi)
Max permitted outlet pressure pB in bar (psi)
Formula to calculate gas outlet pressure pB
Displacement volume in cm3 (ins3)
Air drive pL in bar (psi)
Air consumption in L/min
Gas inlet connection
Gas outlet connection
Air Drive connection
Net weight (kg)
1:60
1:20
–
20 (290)
600 (8,700)
600 (8,700)
60 X pL + pA
120 (7.32)
1-10 (14.5-145)
600-2,400 (21.2-84.8)
1/4 BSP
1/4 BSP
3/4 BSP
23
1:10 / 1:60
1:90
1:6
2 (29)
4 x pL
600 (8,700)
60 X pL + 6 x pA
373 (22.76)
1-10 (14.5-145)
600-2,400 (21.2-84.8)
1/2 BSP
1/4 BSP
3/4 BSP
24
1:30 / 1:60
1:40
1:2.
7 (101)
30 x pL
600 (8,700)
60 X pL + 2 x pA
122 (7.44)
1-10 (14.5-145)
600-2,400 (21.2-84.8)
1/4 BSP
1/4 BSP
3/4 BSP
24
1:75
1:20
-.
35 (507)
750 (10,875)
750 (10,875)
75 X pL
25 (1.52)
1-10 (14.5-145)
400-1,980 (14.1– 69.9)
1/4 BSP
1/4 BSP
3/4 BSP
13